SonoFlex Online manual

Safety Precautions
Disclaimer
Any use that does not comply with the product user manual will be considered "user negligence" and will not be covered under warranty or any related services. Cloudvocal assumes no responsibility for damages to the product or its accessories caused by user negligence.
The user is solely responsible for any damage or impact resulting from improper operation, incorrect signal connection, or external factors, including but not limited to environmental conditions and incompatible power supplies. Cloudvocal is not liable for any direct or indirect losses resulting from user negligence of this product.
This product is not intended for medical, emergency communication, life-support systems, or any applications requiring 100% safety and reliability. Users must comply with local regulations regarding radio frequencies, noise control, and electrical safety standards when using this product.
Excessive volume levels may cause hearing damage and harm audio equipment! Before connecting and using the product, ensure the volume is set to an appropriate level to minimize hearing risks.
- 1.Before use, please read this safety notice and the product user manual carefully.
- 2.Keep this document with the product. When passing the product to another user, be sure to include this document too.
- 3.Only use accessories and connection cables authorized by Cloudvocal.
- 4.Caution: Only dry windshields may be installed on the microphone capsule. Moisture may cause malfunction or damage.
- 5.Connect the microphone only to microphone inputs that provide 48 V phantom power in accordance with IEC 61938.
- 6.Do not attempt to disassemble the product casing. Unauthorized disassembly will void the warranty, and Cloudvocal assumes no responsibility for any damage resulting from such actions.
- 7.For repairs, the product must be serviced by Cloudvocal's designated service provider.
- 8.STOP use and seek repair if the product sustains any form of damage.
- 9.Use the product only within the specified environmental and temperature conditions stated in the document.
- 10.If the product shows visible signs of damage before use, DO NOT use it.
- 11.When connecting cables, ensure proper placement to prevent tripping hazards.
- 12.Prevent the product and its connectors from contacting any liquids or unnecessary electrical sources.
- 13.Do not use solvents or corrosive cleaning agents to clean the product and the accessories.
Manufacturer's Statement & Warranty
For the most up-to-date and valid warranty terms, as well as product registration, please visit our official website: cloudvocal.com/pages/warranty
↑ back to indexAbout SonoFlex

SonoFlex is a condenser microphone specifically designed for capturing the sound of acoustic instruments.
It consists of four main components:
- 1.Microphone capsule
- 2.Gooseneck
- 3.Docking base
- 4.Connection port
The microphone capsule, gooseneck, and docking base are integrated into a single structure. Disassembly is not allowed, as it may result in malfunction or damage.
To use the microphone, attach the docking to the designated instrument mount using the Rotary-Lock mechanism. Once the mic is secured, adjust the gooseneck to position the capsule at the optimal locations.
On live stages, adapter cables can be used to connect to wireless inputs.
Microphone Specifications
3-WIREStandard Mode |
2-WIREWireless Mode |
|
|---|---|---|
| Directional Pattern | Cardioid | Cardioid |
| Cartridge Type | Pre-polarized condenser | Pre-polarized condenser |
| Frequency Response | 20 Hz – 20 kHz | 20 Hz – 20 kHz |
| Sensitivity (±3dB, @1kHz, 0dB=1V/Pa) | −46.2 dB | −43.7 dB |
| Equivalent Noise (A-weighted) | 17.7 dB | 21.3 dB |
| SNR | 76.3 dB | 72.7 dB |
| Dynamic Range | 118.3 dB | 98.1 dB |
| Max SPL (@5% THD) | 145 dB | 132 dB |
| Output Impedance | 29 Ω | Varies with device |
| Current Consumption | 4.5 mA | 0.6 mA |
| Power Requirements | 48V phantom ±4V (IEC 61938) via CLV29 | 5V–10V via CloudVocal wireless cable |
| Operation & Storage Temperature | −10°C ~ +50°C (14°F ~ +122°F) | −10°C ~ +50°C (14°F ~ +122°F) |




Instrument Mounts

| Part Code | Description | Suitable Instruments | Aperture & Range |
|---|---|---|---|
| CM01 | Bell-mounted Mic Clip | Saxophones, Trumpets | Aperture: 4mm · Bell part of the winds |
| CM02 | Violin to Viola Mic Clip | Violin, Viola, Mandolin | Aperture: 35mm – 71mm |
| CM03 | Guitar Mic Clip | Nylon / Steel string guitars | Aperture: 90mm – 126mm |
| CM06 | Elastic Mic Strap | Oboe, Clarinet, Recorder, Bassoon, Flute | Instrument diameter range: 25mm – 65mm |
| CM07 | Universal Mic Clip | Music Stands | Aperture: 4mm |
| CM08 | Suction Mic Mount | Flat Surfaces | Diameter: 4mm |
Docking and the Rotary-Lock
To attach the SonoFlex, align the notch and secure it with a rotary-lock.

How to Mount


Signal Cables and Adapters

XLR Cable
When using SonoFlex in a wired setup, the CLV29 XLR adapter must be used to connect to a 48V phantom power source compliant with IEC 61938 standards.
When using the CLV29 XLR adapter, you can activate the built-in Low Cut switch to apply a 80 Hz low cut filter.
This adapter is designed exclusively for use with the SonoFlex. Do not use it for other purposes.
Adapters for Wireless Transmitters

If you need to connect SonoFlex to a wireless transmitter, Cloudvocal offers various adapter cables, allowing users to connect to different wireless systems.
To accommodate pin configuration differences across brands, the SonoFlex docking includes a 3-wire / 2-wire switch for proper compatibility.
| Part Code | Adapter Type | Wiring Mode | Compatible Brands |
|---|---|---|---|
| CLV29 | XLR male to 3.5mm male | 3 Wire | All XLR inputs with P48 phantom power |
| CW02 | Microdot male to 3.5mm male | 2 Wire | DPA |
| CW03A | 3.5mm male to 3.5mm male | 2 Wire | Sennheiser |
| CW041A | TA4F female to 3.5mm male | 3 Wire | Shure |
| CW041B | TA4F female to 3.5mm male | 3 Wire | Mipro |
Some models may have multiple connector types. Please refer to specific transmitter specs and our pin definition to confirm compatibility.